RUBICON make 3 core flat cables are specialized cables used for submersible pumps in a deep well.
Rubicon Flat cables are manufactured keeping in mind the critical space requirement and also difficult conditions under which they have to operate. Rubicon Cables are manufactured from bright -annealed 99.97% pure bare flexible copper conductor.
Application
Special Features
True Computerized Sequential Marking:Rubicon make cables are available with progressive TRUE computerized SEQUENTIAL MARKING, company name, ISI mark with CML number, size and voltage printed on sheath at every meter throughout the length of the coil or drum.
Technical chart
Construction
Conductor: Flexible Bright Annealed 99.97% pure Electrolytic Grade Bare Copper
Insulation: PVC insulation with higher mechanical and electrical properties.
Sheath: Heat Resistant PVC Type ST2
Voltage Grade - up to and including 1100V
Specification: As per IS 694 1990 & IS 8130 for copper conductor.
3 Core Flat Cables as per IS 694 with ISI mark | |||||||
Conductor | Insulation Thickness (Nom) mm | Sheath Overall Dimentions | Conductor Resistance at 20c (max) ohm/km | Current Carrying Capacity at 40 c Amps | |||
Area Sq mm | No.of Strands/Dia.mm | Thickness(Nom) mm | Width (Approx) mm | Height (Approx) mm | |||
1.5 |
22/0.3* |
0.60 |
0.90 |
12.00 |
5.60 |
12.10 |
14 |
2.5 |
36/0.3* |
0.70 |
1.00 |
14.00 |
6.60 |
7.41 |
18 |
4 |
56/0.3** |
0.80 |
1.10 |
16.50 |
7.40 |
4.95 |
26 |
1. * as per conductor Class 2 of IS:8130-1984,
** as per conductor Class 5 of IS:8130-1984
Note: The strand diameter is nominal. However, construction of conductor is designed to satisfy the requirements of conductor resistance as per IS 8130:1984
3 Core Flat Cables Generally Conforming to IS 694 1990 | |||||||
Conductor | Insulation Thickness (Nom) mm | Sheath Overall Dimentions | Conductor Resistance at 20c(max) ohm/km | Current Carrying Capacity at 40 c Amps | |||
Area Sq mm | No. of Strands/Dia.mm | Thickness (Nom) mm | Width (Approx) mm | Height (Approx) mm | |||
6 |
84/0.3 |
1.00 |
1.10 |
18.70 |
8.10 |
3.30 |
31 |
10 |
140/0.3 |
1.00 |
1.40 |
23.20 |
9.90 |
1.91 |
42 |
16 |
226/0.3 |
1.00 |
1.40 |
28.50 |
12.30 |
1.21 |
57 |
25 |
354/0.3 |
1.20 |
2.00 |
34.10 |
14.80 |
0.780 |
72 |
35 |
495/0.3 |
1.20 |
2.00 |
39.60 |
16.50 |
0.554 |
90 |
50 |
703/0.3 |
1.40 |
2.20 |
45.50 |
18.30 |
0.386 |
115 |
Note: The number of wires and strand diameter will be such as to satisfy the requirements of conductor resistance as per IS 8130:1984